top of page

MIRASYS VMS 9.5 RELEASE NOTES

Automatically takes over the recording of cameras from the broken or unreachable server. Tracks failover activities. VMS Spotter version 9.5: check out the latest features and improvements in the new version of Mirasys Video Management System.


Major News in V9.5

  • Automatically take over recording from broken or unreachable server cameras.

  • Save time and money and take steps to secure the recording even if no system administrator is available.

  • Automatic or manual material copying

  • Use RTSP/RTSPS server to stream video from the server to any third-party client

  • Track all failover activity, with the Failover log

New Features in V9.5


Failback

With the Failback feature, the user can quickly move the server functionality from the failover server back to the fixed server. The user can trigger Manual failback from the failover log.


Automatic or manual material copying

Users can also start material copying from the failover server to the fixed server. This way, the user can secure that all recorded materials can be found from the original server.


RTSP Server

RTSP/RTSPS server is used to stream video from the server to any third-party client that supports RTSP/RTSPS protocol.


Failover log

The Failover log feature was added to the UI in System Manager. Using the failover log administrator can see active and finalised failovers and start manual failback &manual material copying from the failover server.



What's improved in V9.5

  • Shorter time to set to go on PTZ home position

    • New added values; 10 s, 20 s, 30 s, 40 s, 50 s

  • Alphanumeric sorting of device and device groups in the profile ( a -> z)

  • Remove PTZ, take control of prompt and warnings

  • Added the filtering by list type to the live view to the Easy LP

    • Now, the user can filter which lists are shown in the Easy LPR live view

  • Longer periods of playback time limit added

    • Values 1-10 days, 15, 15, 20, 25, and 30 days added

  • Added button to copy pre-and post-recording times to all cameras

    • The user can easily copy pre-and post-recording times to all cameras

  • The failover functionality was renewed to work quicker than before and also can be triggered manually

  • Automatic lock/log offsetting added to the user group level

  • Force user logout

  • Block deletion is added to the user settings.

    • The administrator can now set the Block deletion to the specific user

  • Windows Server 2022 support added

  • SQL Express 2019 is included in the VMS Complete package


What's fixed in V9.5


VMS Server

  • Compatibility issue with old V7 recorders

  • Easy LPR and Axis LPV not working correctly when daylight saving happens

Spotter

  • Problem storyboard video clip playback

  • Realtime audio is stopped if one of the audios is closed

  • Spotter Diagnostic plugin is not working properly

  • Spotter live cause audio click noises, no problem on playback mode

  • Spotter AVM crash when trying to reserve PTZ control when that is already on.

  • Synchronization issue with video and audio when playing from exported clip

  • Spotter is using 100% CPU in big system setup

  • Easy LPR: multiple rows deleted

  • Invalid row in Easy LPR export data

Spotter Web

  • Add IO support to the Spotter Web Mobile version

  • Spotter Web alarms not working properly

  • Spotter Web cameras don't work after quickly switching between tabs

  • Spotter Web streams don't start with correct parameters after logging in

  • Spotter Web closes streaming when the master server starts to make a connection to the offline recorder

  • When adding 4 cameras or more using an Automatic grid, remember only the first camera when the user logs out and logs in

  • Spotter Web can only log in if there is a Spotter role enable

  • Spotter Web continuously streaming option does not work


Important Notes

  • Mirasys VMS V9 is only available as a 64-bit version! A V9 Master Server (Management Server) can handle 32-bit V6 and V7 networked Servers and 64-bit V7, V8 and V9 servers.

  • Mirasys VMS V7.3 and later Releases require Microsoft SQL Server Express or SQL Server Standard (or better) version 2014 when installing the system Master Server, or if the network VMS Servers use Mirasys VCA. Please also note that SQL Server 2014 requires .NET 3.5. And on Windows versions after Windows 7, .NET 3.5 must be turned on (enabled) in Control Panel as a Windows feature (not installed with a separate .NET 3.5 installer)!

  • The "Full" Installer will automatically install the SQL Server Express 2019 or upgrade an earlier SQL installation to 2019 on 64-bit systems. A 32-bit (x86) SQL Server Express 2008 version will not be upgraded to the 64-bit (x64) SQL Server Express 2014. Update SQL manually before updating from an old 32-bit V7 to the latest 64-bit version!

  • The old "Spotter Mobile" does not support Apple iOS 11 or later versions on Apple iPhone or iPad devices. Use the newer "Spotter Seven" instead (requires Mirasys VMS V7 or later).

  • Mirasys VMS V7 End-of-Life date was 31st of March 2021


Supported OS

  • Windows 10 IOT/Pro

  • Windows 11(V9.4 or later)

  • Windows Server 2016

  • Windows Server 2019​

  • Windows Server 2022(since V9.5.0)


Notes on Upgrading to V9

  • All earlier versions can be upgraded to V9.

  • New version types Base, Pro, Enterprise and Enterprise Plus will help reach different market segments.

  • Version 9 will also contain a new user interface for the VCA configuration inside the System Manager.

  • Most VCA settings from V7 or V8 to V9 will be automatically converted but must be reviewed.


V8 End-of-Life (EOL) and V8 End-of-Service (EOS) notification

  • Effective December 31st, 2022, Mirasys is announcing the End of Life or EOL of Mirasys VMS V8.

  • Effective March 31st, 2023, Mirasys is announcing the End of Support or EOS of Mirasys VMS V8. Mirasys reserves the right to discontinue providing support for the VMS V8 license on 31/03/2023. Mirasys Customer Service may consider providing support assistance for End of Support Software at an agreed-upon fee.

Free 12-month SMA

  • Free 12-month SMA offer for new licenses and licenses acquired until December 31st, 2022.


Learn more about the new features or download the new version directly on the Extranet. Any doubt, please contact Mirasys Technical Support.


If you are interested in acquiring Mirasys solutions, get in touch with a Mirasys expert: sales@mirasys.com


תגובות


התגובות הושבתו לפוסט הזה.
bottom of page